Note: SSLo: Fan will be running at Lo speed with Indoor heat
exchanger temperature 1.5 sec ON and 5.5 sec OFF.
- After 30 sec. from compressor OFF (thermo OFF), Indoor fan will
run at SSLo speed only.
- Anti Cold Draft Control will stop when:
- Intake temperature < set temperature -1.5°C. (Time Delay Safety
Control 4 minutes waiting is valid)
- After 30 minutes time saved control.
(see page 22).
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during
heating operation.
- Fan speed rotates in the range of Me
exchanger temperature.
SLo according to the heat