then Soft Dry operation will start.
- During Soft Dry operation, the Indoor Fan will operate and stop at 4-
second intervals at low speed.
- The operation will be switched on and off for up to 10 minutes
"ON" and 6 minutes "OFF". Once Soft Dry operation is turned off,
it stops for 6 minutes.
Time Delay Safety Control
- Once the compressor stops, it will not start for 3 minutes during
Cooling operation.
Starting Current Control
- Same as Starting Current Control for Cooling Mode operation.
Anti-Freezing Control
- Same as Anti-Freezing Control for Cooling Mode operation. (For
Soft Dry region, 6 minutes waiting is valid during compressor
stops.) /
Compressor Reverse Rotation Protection Control
- Same as Compressor Reverse Rotation Protection Control for
Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting is
valid during compressor stops.)
Compressor Protection Control
- Same as Compressor Protection Control for Cooling Mode
Operation.
22