Accessories
Accessories supplied with the outdoor unit:
A
Installation manual
C
Drain cap (1)*

Precautions for Selecting the Location

1) Choose a place solid enough to bear the weight and vibration of the unit, where the operating sound will not be amplifi ed.
2) Choose a location where the hot air discharged from the unit or the operating sound will not cause a nuisance to the
neighbours of the user.
3) Avoid places near a bedroom and the like, so that the operating sound will cause no trouble.
4) There must be suffi cient spaces for carrying the unit into and out of the site.
5) There must be suffi cient space for air passage and no obstructions around the air inlet and the air outlet.
6) The site must be free from the possibility of fl ammable gas leakage in a nearby place.
7) Install units, power cords and inter-unit wire at least 10ft (3m) away from television and radio sets. (This is to prevent
interference to images and sounds. Noise may be experienced even if they are more than 10ft (3m) away depending on radio
wave conditions.)
8) In coastal areas or other places with a salty atmosphere or one containing sulphate gas, corrosion may shorten the life of the
air conditioner.
9) Since water will fl ow from the drain of the outdoor unit, do not place under the unit anything which must be kept away from
moisture.
NOTE
Cannot be installed suspended from ceiling or stacked.
CAUTION
When operating the air conditioner in a low outdoor ambient
temperature, be sure to follow the instructions described below.
• To prevent exposure to wind, install the outdoor unit with its
suction side facing the wall.
• Never install the outdoor unit at a site where the suction side
may be exposed directly to wind.
• To prevent exposure to wind, it is recommended to install a
baffl e plate on the air discharge side of the outdoor unit.
• In heavy snowfall areas, select an installation site where the
snow will not affect the unit.
3
09/12 class
18/24 class
B
Drain socket*
1
It is on the bottom packing case.
D
Drain cap (2)*
4
6
09/12 class
18/24 class
*Only for heat pump models.
• Construct a large canopy.
• Construct a pedestal.
Install the unit high enough off
the ground to prevent burying
in snow.
1
2
3
English