Safety Guidelines For Hazardous Locations - National Instruments NI-9269 Getting Started

Hide thumbs Also See for NI-9269:
Table of Contents

Advertisement

Withstand
1,390 V RMS, verified by a 5 s dielectric withstand test
Channel-to-earth ground
Continuous
250 V RMS, Measurement Category II
Withstand
2,300 V RMS, verified by a 5 s dielectric withstand test
Division 2/Zone 2 hazardous locations applications (Channel-
to-channel and channel-to-earth ground)
Note
Measurement Categories CAT I and CAT O are equivalent. These test
and measurement circuits are for other circuits not intended for direct
connection to the MAINS building installations of Measurement Categories
CAT II, CAT III, or CAT IV.

Safety Guidelines for Hazardous Locations

The NI-9269 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous
locations; Class I, Zone 2, AEx nA IIC T4 Gc and Ex nA IIC T4 Gc hazardous locations;
and nonhazardous locations only. Follow these guidelines if you are installing the
NI-9269 in a potentially explosive environment. Not following these guidelines may
result in serious injury or death.
Caution
Do not disconnect I/O-side wires or connectors unless power has
been switched off or the area is known to be nonhazardous.
Caution
Do not remove modules unless power has been switched off or
the area is known to be nonhazardous.
Caution
Substitution of components may impair suitability for Class I,
Division 2, or Zone 2.
NI-9269 Getting Started
60 V DC, Measurement Category I
© National Instruments
5