Classifi-
cation of
No.
Parameter name
parameters
Other
P76
Repetitive machining time
settings
(min)
P77
Repetitive machining inter-
val (s)
P78
Work ending position
P395
Template recognition meth-
od
P81
Interface style
P681
Motion mode is started
before operation
P755
Jump mode during opera-
tion
P241
Connection to the extend-
ed screen
P79
Reverse feed after main
shaft needle stops
P242
Voice prompt
P21
Enabling the memory func-
tion during power failure
P194
File is enabled when the
electronic tag separates
from it
Standard
Range
value
1 to 65535
1440
0 to 20
0
Return to 0
Return to
(zero) / sewing
0 (zero)
starting position
/ default
Barcode / elec-
Electronic
tronic tag
tag
Classic / simple Classic
XY simul-
XY simul-
taneous / X
taneous
precedence / Y
precedence
X precedence /
XY simul-
Y precedence /
taneous
XY simultane-
ous
Yes/No
No
0 to 160
50
High / medium /
OFF
low / OFF
Enable / disable Enable
Enable / disable Disable
– 45 –
Meaning of parameter and comment
Cyclic machining total time: When the
set time has elapsed, cyclic machining
is stopped
Interval from the completion of machin-
ing to re-starting of machining under
the cyclic machining mode
Return to 0 (zero): All of x / y axes
coordinates return to 0 (zero); sewing
machine terminates sewing; reset point
Right side: Rightmost position within
the machining range
Sewing starting position: First sewing
point of the machining file
Default: The sewing machine stops
after the completion of machining
By serial number of file: Barcode identi-
fication mode
By file name: Electronic tag identifica-
tion mode
Classic: Button style of the virtual body
Simple: Flat button style
Jump travel mode
In the case of "Yes", information on the
operation file can be displayed on the
external add-on display
"High", "medium" and "low" respective-
ly refer to the magnitude of sound
After re-energization of the sewing
machine, the sewing sequence carried
out before power failure is resumed to
continue sewing from that interrupted
sequence.