Water Inlet Valve
The water inlet valve is electronically controlled and
solenoid-operated. The
by a rubber
ow washer capable of maintaining a
ow rate of 1.8 ±14% gallons per minute (6.81 ±14%
liters per minute) with incoming water pressure
of 20 to 120 PSI. The water valve is mounted on a
bracket located on the left side of the front brace.
The water valve has an approximate resistance

value of 1 K
and is energized for
seconds during each
ll.
Operation of the water valve can be checked by
using the service test mode. (See
To remove the water valve:
1. Disconnect power.
2. Remove the outer door panel. (See
.)
Panel
3. Remove the 2 Phillips-head screws, washers,
and the access panel.
4. Disconnect the water supply line from the
valve inlet .
5. Remove the 2 Phillips-head screws that hold the
bracket to the front brace.
6. Disconnect the 2 wires from the solenoid.
Bracket
Disconnect
Caution:
The clamp is easily damaged during
removal and should not be reused. Use the screw-
ty pe hose clamp provided with the new valve.
ow of water is controlled
approximately 36
Service Test Mode
Outer Door
ll
Inlet
7. Remove the clamp and the outlet hose from the
valve.
Outlet Hose
.)
8. Remove the four 1/ 4-in. hex-head screws and
the
ll valve from the bracket .
Note: Ensure the O-ring is retained in the valve upon
reassembly .
– 24 –
Clamp
O-Ring