https://appliancetechmanuals.com
3. Pull the top of the vent out while lifting up to
clear the bottom of the dishwasher.
Static Dry Vent
Note:
•
Inspect the cover for hard water/ lime deposits
or debris, and clean if necessary .
•
If the control panel gasket shows obvious signs
of wear or damage, replace the gasket .
•
If the vent cover O-ring shows obvious signs of
wear or damage, replace the static dry vent .
O-Ring
Static Dry Vent
Control Assembly
The control assembly consists of 2 PCB user
interface boards and a power board.
To remove the PCB user interface assembly:
1. Disconnect the power supply to the dishwasher.
2. Remove the control panel. (See
3. Remove the 2 Phillips-head screws that attach
the power board cover to the power board.
4. Disconnect 2 wire harnesses from the power
board.
5. Cut the plastic tie that holds the wires to the
control panel.
Disconnect
6. Remove 3 Phillips-head screws from the cy cle
select PCB user interface board.
– 17 –
.)
Control Panel
( Continued next page )