GFK-2884K

Specifications

Specification
PROFINET support
RX3i Controller version
required
RXi Controller version
required
PAC Machine Edition version
required
Power requirements
1
Module dimensions
Operating temperature
Number of Ethernet port
connectors
USB connector (for firmware
upgrades)
PNS status and control bits
I/O data update on the
PROFINET LAN
Number of IP addresses
Number of MAC addresses
I/O station maximum limits
Configuration
Note:
For product standards, general operating specifications, and installation requirements, refer to GFK-2314, PACSystems RX3i System
Manual.
_________________________
1
Value does not include the power consumption of the installed I/O modules. When calculating the total power requirements, add the power consumption of
the I/O modules according to the I/O module datasheet.
Description
PROFINET Version 2.3 Class A IO-Device
CPU320/CPU315 Primary Firmware Release 8.95 or later
CPU320/CPU315 Boot Firmware Release 5.10 or later
CPE310/CPE305 Primary Firmware Release 8.95 or later
CPE310/CPE305 Boot Firmware Release 7. 10 or later
CRU320 Primary Firmware Release 8.95
CRU320 Boot Firmware Release 5.10 or laterIC69PNC001 PROFINET IO-controller with firmware
version 2.26 or later
RXi Controller, ICRXICTL000, with firmware version 7.80 or later is compatible with CEP001 up to
version 2.01 but is not compatible with CEP001 version 2.30.
Version 8.6 with SIM 3 or later
IC695CEP001: 5.25W (0.22 A) at 24 Vdc with or without Expansion Carrier (IC694CEE001)
DC power supply input range: 19.2 to 30 Vdc
177.2 x 51 x 35 mm (6.98" x 2.01" x 1.38"). Same for CEP001 and CEE001.
0°C to 60 °C (32°F to 140 °F) maximum surrounding air temperature
IC695CEP001: Two RJ-45 10/100Base-TX receptacles
IC694CEE001: None
IC695CEP001: One Micro-B connector. USB 2.0 compliant running at full-speed (12 MHz) in device
mode
IC694CEE001: None
32 input status bits and 32 output control bits
Configurable: 1 ms, 2 ms, 4 ms, 8 ms, 16 ms, 32 ms, 64 ms, 128 ms, 256 ms and 512 ms
One; supports Classless Inter-Domain Routing (CIDR)
Three; one per external port and one internal. External MAC addresses are only used for specialized
Ethernet protocols such as MRP or LLDP.
Number of I/O modules per station
I/O data per station
Configured using PAC Machine Edition when used with a PACSystems RX3i PROFINET Controller
module as part of an RX3i High-speed I/O LAN system.
V2.3 GSDML file available for import into 3rd-Party tools.
IC695CEP001:
IC695CEP001 with IC694CEE001:
1024 bytes total
512 bytes of input data
512 bytes of output data
Feb 2022
One
Two
3