GFK-2884K
Configuring the CEP001/CEE001 Node and Resident I/O Modules on a PROFINET Network
PAC Machine Edition is the primary tool used to configure an RX3i PROFINET network. The GSDML file for the RX3i
CEP001 is included with PAC Machine Edition or may be downloaded from the support website. See links provided at
the end of this document.
To obtain the GSDML for import into a 3rd-Party tool, contact Emerson.

Supported I/O Modules

The following table indicates the minimum CEP001 firmware version required for compatibility with the listed I/O
modules and whether the module can be installed in the RX3i Expansion Carrier CEE001.
Catalog
Module Description
Number
Discrete Input Modules
IC693MDL230
8 Circuit Input 120 Vac Isolated
IC693MDL231
8 Circuit Input 240 Vac Isolated
IC693MDL240
16 Circuit Input 120 Vac
IC693MDL241
16 Circuit Input 24 Vac / Vdc
IC693MDL260
32 Circuit Input 120 Vac, Input Filtering Off
IC693MDL260
32 Circuit Input 120 Vac, Input Filtering On
IC693MDL632
8 Circuit Input 125 Vdc Positive / Negative Logic
IC693MDL634
8 Circuit Input 24 Vdc Positive / Negative Logic
IC693MDL635
16 Circuit Input 125 Vdc Positive / Negative Logic
IC693MDL645
16 Circuit Input 24 Vdc Positive / Negative Logic
IC693MDL648
16 Circuit Input 48 Vdc Positive / Negative Logic Fast
IC693MDL654
32 Circuit Input 5/12 Vdc Positive / Negative Logic
IC693MDL655
32 Circuit Input 24 Vdc Positive / Negative Logic Fast
32 Circuit Input 24 Vdc Positive / Negative Logic, Input
IC693MDL660
Filtering Off
32 Circuit Input 24 Vdc Positive / Negative Logic, Input
IC693MDL660
Filtering On
IC694MDL230
8 Circuit Input 120 Vac Isolated
IC694MDL231
8 Circuit Input 240 Vac Isolated
IC694MDL240
16 Circuit Input 120 Vac
_________________________
2
The RX3i CEP Carrier and the RX3i CEP Expansion Carrier currently does not support fault reporting or "Interrupts" from this module.
3
The RX3i CEP Carrier and the RX3i CEP Expansion Carrier currently does not support all HART features in this module. HART
HART Device Information COMMREQ support only (no HART variables in IO Data). HART-compatible CPU and PNC001 versions are required.
The RX3i CEP Carrier and the RX3i CEP Expansion Carrier cannot distinguish between modules within the same Distinguishing Class type.
This means that any module physically present that is within the same class as the one configured will not alert the user with a System
Configuration Mismatch fault on the Controller Fault Table. Refer to GFK-2222 Chapter 3 for CPU operation during System Configuration
Mismatch faults.
Earliest
Distin-
CEP001
guishing
Compatible
Classes
2
Version
8 in
2.30
8 in
2.50
16 in
2.30
16 in
2.50
32 in
2.50
32 in/32 out
2.50
8 in
2.30
8 in
2.50
16 in
2.30
16 in
2.40
16 in
2.30
32 in
2.50
32 in
2.50
32 in
2.30
32 in/32 out
2.30
8 in
2.30
8 in
2.50
16 in
2.30
®
Pass Through or Remote Get
Feb 2022
CEE001
3
Comp-
atible
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
12