6. Check with a magnifier for solder bridge between the pins or for
dry joint between pins and soldering pads. To remove a solder
bridge, use a de solder braid as shown in the figure below
IMPORTANT
To protect against possible damage to the solid state devices due to arching or static discharge,
make certain that all ground wires and CRT DAG wire are securely connected.
CAUTION
The power supply circuit is above earth ground and the chassis
cannot be polarized. Use an isolation transformer when servicing
the receiver to avoid damage to the test equipment or to the
chassis. Connect the test equipment to the proper ground(hot) or
(cold) when servicing, or incorrect voltages will be measured.
2.1. X-Ray Protection Circuit Check & Adjustments
This test must be performed as final check before the receiver is returned to the customer. If
voltages are out of tolerance, immediate service and correction is required to insure safe
operation and to prevent the possibility of premature componentfailure.
Equipment:
1. Isolation transformer.
2. High voltage meter.
3. D.C. Ammeter
4. Short jumper.
5. HHS jig (See figure below).
Diode Connection Jumper.
7