Panasonic CT-27SL13MUG Service Manual page 58

Table of Contents

Advertisement

center mark.
2. Adjust linearity data "V-C" so that interval of "a" is same as "b" (a
=b).
3. If the v-position is not at the CRT center, adjust / V position "V
POS" DATA again.
4. Apply a monoscope pattern.
5. Confirm that center horizontal line is in center mark on CRT.
6. Adjust "VEAMP" register for correct vertical size by making
monoscope round circle leaving 4 marks off the CRT edge.
12.6.3.
V-S Correction adjustment
PREPARATION
1. Apply a crosshatch pattern
2. Normalize the picture settings.
PROCEDURE
1. Enter to service mode
2. Check a and b sizes, If b-a < -1.5mm (in top & bottom extending
Vertical centering adjustment.
30