3. Humidifying Rotor Motor
Warning
Step
1. Remove the humidifying
rotor.
1
Release the
hygroscopic fan motor
lead wire from the hook.
Remove the bell mouth.
2
Remove the
3
humidifying rotor.
2. Remove the humidifying
rotor motor.
Disconnect the
1
humidifying rotor motor
lead wire.
Remove the 2 screws
2
and remove the
humidifying rotor motor.
6
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Hook
Humidifying
rotor motor
Hygroscopic fan motor
lead wire
(R19576)
Bell mouth
(R19577)
Humidifying
rotor
(R19578)
Humidifying rotor
motor lead wire
(R19579)
Si001362E