Maintenance - Bradford White FVIR Defender Safety System RG240T6N394264475 Installation/Operation Instruction Manual

Gas-fired water heater
Table of Contents

Advertisement

Water heaters are heat producing appliances. To avoid damage or injury there
shall be no materials stored against the water heater or vent-air intake system,
and proper care shall be taken to avoid unnecessary contact (especially by
children) with the water heater and vent-air intake system.
UNDER NO CIRCUMSTANCES SHOULD FLAMMABLE MATERIALS, SUCH
AS GASOLINE OR PAINT THINNER BE USED OR STORED IN THE VICINITY
OF THIS WATER HEATER, VENT-AIR INTAKE SYSTEM OR IN ANY
LOCATION FROM WHICH FUMES COULD REACH THE WATER HEATER OR
VENT-AIR INTAKE SYSTEM.
The water heater should be inspected at a minimum annually by a qualified
service technician for damaged components and/or joints not sealed. DO
NOT operate this water heater if any part is found damaged or if any joint is
found not sealed.
The following maintenance should be performed by a qualified service technician at the
minimum periodic intervals suggested below. In some installations, the maintenance
interval may be more frequent depending on the amount of use and the operating
conditions of the water heater. Regular inspection and maintenance of the water heater
and vent-air intake system will help to insure safe and reliable operation.
1.
Annually check the operation of the thermostat.
2.
The flow of combustion and ventilation air must NOT be restricted. Make sure
slots in jacket are open and unobstructed. Clear jacket slot openings of any dirt,
dust, or other restrictions.
3.
At all times keep the water heater area clear and free from combustible materials,
gasoline and other flammable vapors and liquids.
4.
Bi-annually conduct a visual check of the main and pilot burner flames to
determine that they are burning properly. See Burner Flame Check section of this
installation and operation manual. If sooting or other burner anomalies are evident,
shut down the water heater by turning off the gas per the instructions listed in this
manual or as listed on the water heater.
5.
Annually remove the inner door and main burner assembly to clean orifices and
related parts of any dirt or other foreign material. Inspect the burner ports for
obstructions or debris and clean with a wire brush as needed. Wire brush and/or
vacuum clean the combustion chamber as needed to remove scale deposits and
debris. NOTE: It is imperative for proper operation of the water heater that the
inner door be replaced in the original location, making certain the resettable
thermal switch is properly connected to the gas control wire leads provided.

MAINTENANCE

WARNING
IMPORTANT
WARNING
The ventilation air system may be HOT.
22

Advertisement

Table of Contents
loading

Table of Contents