Water heaters are heat producing appliances. To avoid damage or injury there
shall be no materials stored against the water heater or vent-air intake system,
and proper care shall be taken to avoid unnecessary contact (especially by
children) with the water heater and vent-air intake system. UNDER NO
CIRCUMSTANCES SHOULD FLAMMABLE MATERIALS, SUCH AS
GASOLINE OR PAINT THINNER BE USED OR STORED IN THE VICINITY OF
THIS WATER HEATER, VENT-AIR INTAKE SYSTEM OR IN ANY LOCATION
FROM WHICH FUMES COULD REACH THE WATER HEATER OR VENT-AIR
INTAKE SYSTEM.
To Fill The Water Heater
1.
Close the water heater drain valve by turning the knob clockwise
2.
Open the cold-water supply shut-off valve.
3.
Open several hot water faucets to allow air to escape from the system.
4.
When a steady stream of water flows from the faucets, the water heater is filled.
Close the faucets and check for water leaks at the water heater drain valve,
combination temperature and pressure relief valve and the hot and cold-water
connections.
To Drain The Water Heater
Should it become necessary to completely drain the water heater, make sure you
follow the steps below:
1.
For the White Rodgers mechanical control, rotate the thermostat dial clockwise
to the lowest possible position, OR for the Honeywell and the White
Rodgers electronic controls, rotate the thermostat dial counter-clockwise
the lowest possible position.
2.
For the White Rodgers mechanical control, partially depress and rotate the gas
control knob clockwise
3.
Shut OFF the gas supply to the water heater.
4.
Close the cold-water supply shut-off valve.
5.
Open the drain valve on the water heater by turning the knob counter-clockwise
. The drain valve has threads on the end that will allow the connection of a
standard hose coupling.
Open a hot water faucet to allow air to enter the system.
6.
To refill the water heater, refer to "To Fill the Water Heater."
Wait at least 2 minutes after this control is pressurized with gas before attempting
to light pilot and/or push igniter button. Failure to do so may result in severe injury.