Comms > Dialler Reporting >
Burg Report Delay
Enter 0 – 255 seconds + [OK] To Program The Delay Time In Seconds
Before Reports Are Sent. 0 = No Delay
Comms > Dialler Reporting >
Fire Report Delay
Enter 0 – 255 seconds + [OK] To Program The Delay Time In Seconds
Before Reports Are Sent. 0 = No Delay
Comms > Comms Test >
Send Test Report
Comms > Comms Test >
Test Report Time
Use the [] and [] keys to move to the field then [] and [] to
change. Press [OK] to save or [MENU] to exit without saving.
���� �� ���������� �� ������ �������
i
Note
Comms > Comms Test >
Test Report Period
0 = No Test Report
1 = Every Day
2 = Every Week
3 = Every Month
MENU 5-9-2 Programs The Interval Between Automatic Test Reports.
Enter [0] to [3] + [OK] To Program the required value.
(*** System Wide Parameter ***)
Comms > Comms Test >
Test Report Options
1
Send Test Reports Only If No Other Report
2
Send Test Reports On Siren Reset / Time Out
3
Reserved
4
Reserved
5
Reserved
6
Reserved
7
Reserved
8
Reserved
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
Bosch Security Systems 09/07 BLCC500R FTR1.02
MENU 5-4-6
0
0
SECONDS
(*** System Wide Parameter ***)
MENU 5-4-7
0
0
SECONDS
(*** System Wide Parameter ***)
MENU 5-9-0
MENU 5-9-1
Test Time
02
:
00
HH
MM
MENU 5-9-2
MENU 5-9-3
Copyright © 2007
Comms > Comms Test >
Test Route
0 = Report Events To Log Only
0
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
Enter 0 - 4 + [OK]. To Enter Single Option Only.
(*** System Wide Parameter ***)
0
Comms > Comms Test >
Dial Number Test
Use the option to test the system dialer to your mobile or other phone.
Enter the digits to dial and press OK. The system will call the number
entered. This function will stop after 30 seconds or by pressing OK.
Enter [0] – [9] For Telephone Digits.
Use [] and [] To Toggle Special Characters  # and , (Pause)
De vi ce Program m i n g
Devices > Commands >
LAN Status
LAN Secure
Devices > Keypads >
Keypad Volume
Keypad Contrast
Keypad Backlight
Devices > Keypads >
Home Area
1
Enter 1 - 4 Then Press [OK] To Set The Home Area. This is the Area
which will be diplayed on the keypad by default.
All keypads must have a home area programmed
i
to work correctly.
Note
Devices > Keypads >
General Options
1
Keypad Extinguish
2
Greeting On Arming
N
3
Greeting On Disarming
Y
4
Enable Rear Tamper
N
5
PIN To Change Area
N
6
Home Area Only
N
7
Report/Display Keypad Temperature
N
8
Display Area ICON Indicators
N
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
N
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
E&OE
Solution 16 i
Quick Start Guide
MENU 5-9-4
MENU 5-9-5
MENU 6-0-0
MENU 6-0-1
MENU 6-1-0
MENU 6-1-1
MENU 6-1-2
MENU 6-1-3
MENU 6-1-4
1
1
N
Y
Y
N
N
N
N
N
37