Bosch Solution 16i Quick Start Manual page 36

Hide thumbs Also See for Solution 16i:
Table of Contents

Advertisement

Solution 16 i
Quick Start Guide
Comms > Remote Access >
DTMF Options
1
DTMF Arming
2
DTMF Disarming
3
DTMF User Functions
4
DTMF Quick Arm ([0] + [#])
5
Reserved
6
Reserved
7
Reserved
8
Reserved
This location is a Bit option field. Press Keys [1] – [8] to turn ON and
OFF the required options. The option is selected or ON when the
coresponding zone indicator is on. Press [OK] To Save when finished.
Comms > Remote Access >
Voice Access Code
If a Voice Module is used enter the 2-digit access code used to access the
system. Enter [0] – [9] For Digits and Use [] and [] To Toggle Special
Characters.
Comms > Remote Access >
CLI Number
1
First
Number
1
Second
Number
1
Third
Number
Use [] and [] Keys To Scroll Cursor. Enter [0] – [9] For Telephone
Digits. Use [] and [] To Toggle Special Characters  # and , (Pause)
Up to 3 Phone numbers can be entered for CLI
i
remote access detection. You must enter STD code
Note
plus the compete number for this option to work.
Press [OK] after each telephone number is entered
to save and move to the next number.
Comms > Remote Access >
User RAS Security PIN
Use keys 0 - 9 To Program RAS Security PIN + [OK] To Save. This PIN
is used the authenticate during end user remote access connections.
Comms > Dialler Reporting >
TX Format Dest 1
0 = Disable
1 = Contact ID
7 = Domestic
2 = SIA
8 = Voice
3 = Serial STU
9 = SIA +
4 = GSM
10 = Reserved
5 = WEB MAIL
11 = Reserved
6 = SMS
12 = Reserved
Enter 0 – 15 Then Press [OK] To Program The Transmission Format The
Control Panel Will Use To Report To Destination 1.
Only 1 Option Can Be Programmed In This Location.
36
MENU 5-3-5
MENU 5-3-6
MENU 5-3-7
Digits
Digits
Digits
MENU 5-3-8
0
0
0
0
0
0
MENU 5-4-0
13 = Reserved
14 = Reserved
15 = Reserved
Copyright © 2007
Comms > Dialler Reporting >
TX Format Dest 2
0 = Disable
Y
1 = Contact ID
N
2 = SIA
N
3 = Serial STU
Y
4 = GSM
N
5 = WEB MAIL
N
6 = SMS
N
Enter 0 – 15 Then Press [OK] To Program The Transmission Format The
N
Control Panel Will Use To Report To Destination 2.
Only 1 Option Can Be Programmed In This Location.
Comms > Dialler Reporting
Test Route
0 = Report Events To Log Only
9
#
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
Location 5-4-2 Sets The Report Route For Test Reports.
Enter 0 - 4 + [OK]. Only One Option Can Be Selected.
(*** System Wide Parameter ***)
32
Comms > Dialler Reporting
32
Status Route
0 = Report Events To Log Only
32
1 = Report Events To Destination 1 + Log
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
Location 5-4-3 Sets The Report Route For System Status Reports.
Enter 0 - 4 + [OK]. Only One Option Can Be Selected.
(*** System Wide Parameter ***)
Comms > Dialler Reporting
Emergency Route
0 = Report Events To Log Only
1 = Report Events To Destination 1 + Log
0
0
2 = Report Events To Destination 2 + Log
3 = Report Events To Destination 1 & Destination 2 + Log
4 = Report Events To Destination 2 If Destination 1 Fails + Log
Location 5-4-4 Sets The Report Route For All Emergency Reports.
Enter 0 - 4 + [OK]. Only One Option Can Be Selected.
(*** System Wide Parameter ***)
1
Comms > Dialler Reporting >
Swinger Dialler
Enter 0 – 15 + [OK] To Program Number Of Times The Dialler Can
Report Before Lockout.
0 = Unlimited Attempts
E&OE
7 = Domestic
8 = Voice
13 = Reserved
9 = SIA +
14 = Reserved
10 = Reserved
15 = Reserved
11 = Reserved
12 = Reserved
(*** System Wide Parameter ***)
Bosch Security Systems 09/07 BLCC500R FTR1.02
MENU 5-4-1
1
MENU 5-4-2
1
MENU 5-4-3
1
MENU 5-4-4
1
MENU 5-4-5
0
6

Advertisement

Table of Contents
loading

Table of Contents