IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 61000-4-18
IEC 61000-4-29
a
Siemens-specified severity levels
EMC Immunity Type Tests per IEEE 1613
Note
RUGGEDCOM products meet Class 1 requirements for copper Ethernet
configurations and Class 2 for fiber Ethernet configurations. Class 1 allows for
temporary communication loss, while Class 2 requires error-free and interrupted
communications.
Radiated RFI
Fast Transient
RUGGEDCOM M2200F
Installation Manual, 04/2022, C79000-G8976-1343-09
Test
Damped
Oscillatory
Mains Frequency
Voltage
Ripple on DC
Power Supply
Damped
Oscillatory Wave
Voltage Dips
and Interrupts
IEC 60255-5
Dielectric Strength
HV Impulse
Description
ESD
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
6.2 EMC and Environmental Type Tests
Description
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
AC and DC
Power Ports
DC Power Ports
Slow Damped
DC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Certification
Test Levels
Severity Levels
2.5 kV Common
1 kV Differential
Mode @1 MHz
30 V Continuous
300 V for 1s
10%
2.5 kV Common
Mode on Power
and Signal
1.0 kV Differential
Mode on Power
30% for 0.1 s
60% for 0.1 s
100% for 0.05 s
2 kV (Fail-Safe
Relay Output)
2 kV
2 kV
5 kV (Fail-Safe
Relay Output)
5 kV
Test Levels
±2 kV
±4 kV
±8 kV
±4 kV
±8 kV
±15 kV
35 V/m
4 kV @ 2.5 kHz
4 kV
3
4
3
3
 
 
 
 
 
 
 
35

Advertisement