Be careful of the direction the F.P.C.is connected to the connector as shown.
6.1.3. SELF-DIAGNOSTIC SYSTEM FOR SD C.B.A.
Perform the following test procedures.
1. Connect a TV Monitor.
2. Set the unit to SD mode.
3. Eject the cassette tape from the VCR Mechanism.
4. Insert the SD Card with stored still image data (JPEG) in
[IMEXPORT] folder.
5. Press STOP button on the VCR and 1 key on the remote together.
The test results will be displayed on the TV Monitor.
6.1.4. REPLACEMENT PROCEDURES FOR CSP (CHIP SIZE PACKAGE) IC
6.1.4.1. EQUIPMENT
1. Spot Heater
2. Vacuum Pick-up
3. P.C.B. Holder
Fig. 15
44