Code
1015h
The pattern read back from the cache is
not the same as the pattern written.
1016h
Tag Write with Data Read command
failed.
1017h
Tag Read with Data Read command
failed.
1030h
L2 Cache Pattern error.
1031h
L2 Cache Parity error.
1081h
No active external cache memory.
Explanation
1000h – 10FFh: Multiple Processor Error Codes
Details/Parts to Check
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new:
L2 memory (if installed in accessory slot), or
processor (if integrated on the processor card).
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new:
L2 memory (if installed in accessory slot), or
processor (if integrated on the processor card).
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new:
L2 memory (if installed in accessory slot), or
processor (if integrated on the processor card).
Cache memory error.
Check processor, L2 cache and main memory are
correctly installed.
Run memory tests to confirm correct function of
main memory and any external L2 cache memory.
If error persists, replace processor.
Cache memory error.
Check processor, L2 cache and main memory are
correctly installed.
Run memory tests to confirm correct function of
main memory and any external L2 cache memory.
If error persists, replace processor.
Cache memory error.
Enable external cache memory from BIOS setup.