Storage and Transportation

CAUTION: Never place any type of storage cover on the generator while it is still
hot.
When transporting your generator:
Empty the gas tank (see "Emptying the Gas Tank" in the "Maintenance" section).
Disconnect the spark plug.
Do not obstruct any ventilation openings & keep the generator in a cool, dry area.
Storage Period
If you plan on starting
the same day
If you plan on starting
the unit again within
30 days
If you do not plan to
start the unit for
longer than 30 days
Storage Preparation
1.
Turn off the main breaker.
2.
Allow the unit to run 3 - 5 minutes.
3.
Turn off the battery switch.
4.
Store.
1.
Turn off the main breaker.
2.
Allow the unit to run 3 - 5 minutes.
3.
Turn off the fuel valve.
4.
Allow the unit to stall out.
5.
Turn off the battery switch.
6.
Add fuel stabilizer to the gas remaining in the tank.
7.
Store.
1.
Turn off the main breaker.
2.
Allow the unit to run 3 - 5 minutes.
3.
Turn off the fuel valve.
4.
Allow the unit to stall out.
5.
Turn off the battery switch.
6.
Drain the fuel tank (See "Emptying the Gas Tank" in the "Maintenance" section)
7.
Drain the carburetor
a.
Remove the drain bolt from the carburetor.
b.
Drain the small amount of remaining fuel from the carburetor bowl.
8.
Oil the cylinder
a.
Remove the spark plug.
b.
Put 2 tbsp. of 10w30 motor oil directly into the spark plug hole.
c.
Pull the recoil start one time.
d.
Replace the plug.
9.
Remove the battery and place it on tender indoors.