Starting The Generator Using Remote Start - DUROMAX XP13000HXT User Manual

Hide thumbs Also See for XP13000HXT:
Table of Contents

Advertisement

STARTING THE GENERATOR (CONTINUED)

Starting the Generator Using Remote Start

42
1.
Shut breaker off
The breaker is located on the right side of the front power
panel. Flip the breaker down to prevent accidental load
when starting the generator.
2.
Select your fuel.
If using gasoline, see step 2 on pg. 32. If using propane see
steps 2 - 5 on pg. 34. If using natural gas see steps 2 - 5 on
pg. 36.
3.
Turn battery switch ON
The battery switch is located on the top center of the main
power panel. Turn the switch ON to allow power to the
push-button start.
4.
Turn idle control OFF
The idle control is located on the top center of the main
power panel. Turn the switch OFF to prevent the unit from
trying to idle down before the engine is warmed up.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents