STARTING THE GENERATOR (CONTINUED)

Starting the Generator Using Propane

34
1.
Turn breaker off
The breaker is located on the right side of the front power
panel. Flip the breaker down to prevent accidental load
when starting the generator.
2.
Turn gas type to propane
The fuel switch is located on the left front panel. Rotate the
switch to the Propane position to turn on the fuel supply.
3.
Connect propane hose
The propane inlet is located on the left-hand front panel to
the right of the fuel switch. Securely connect the propane
hose to the inlet.
4.
Turn fuel type to propane
The fuel switch is located on the left front panel. Rotate the
switch to the Natural Gas/Propane position to turn on the
fuel supply.