Yaesu DR2XLAN Operating Manual page 27

Vhf/uhf c4fm/fm 50w ams digital repeater
Table of Contents

Advertisement

While the TOT is activated, transceivers may communicate without changing the transmit DG-ID for a certain
period of time (TOT operating time) regardless of the transceiver DG-ID.
ø: Selectable from 0/30sec/1min/1.5min/2min/2.5min/3min/4min/5min/10min/CONT. (Default 1min)
• When deactivating the TOT, transceiver beeps 2 times to notify that the TOT is deactivated with the downlink
signal from all the linked repeaters.
• When RPT-D is performing local communication etc. and TOT is activated, it cannot be accessed from other
repeaters. Transceiver beeps 3 times to notify that the accessed repeater failed to activate the downlink of
the accessed repeaters.
z Register all the DG-IDs used in the group for each DR-2X/DR-2XE.
In the RPT Group, DG-ID registration screen of RPT-A, register all the DG-ID numbers 01,02, 03, 04, 10, 20,
50 used within the group members.
Similarly, all the DG-ID numbers 01, 02, 03, 04, 10, 20, 50 used in the group are also registered in RPT-B,
RPT-C, RPT-D.
DR-2X / DR-2XE Operating Manual
25

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dr-2xeDr-2x

Table of Contents