Changing the Needle

CAUTION:
Turn OFF the power switch before changing the
needle.
Raise the needle to its highest position by turning the
handwheel counterclockwise, and lower the presser
foot.
A loose needle or a loose screw may cause machine
malfunction or needle to break.
Loosen the needle clamp screw by turning it
counterclockwise with a screwdriver. Remove the needle
from the needle clamp.
Insert a new needle into the needle clamp with the flat
w
side to the rear. When inserting the needle into the
needle clamp, push it up as far as it will go.
Tighten the needle clamp screw firmly by turning it
clockwise with a screwdriver.
q Needle clamp screw
w Flat side
To see if the needle is in good condition, place the flat
side of the needle onto something flat (needle plate, glass
etc.). The gap between the needle and the flat surface
should be consistent. Never use a bent or blunt needle.
A damaged needle can cause permanent snags or runs
in knits, fine silks and silk-like fabrics.