Site Preparation; Installation Site Requirements - Follett Horizon Elite HCD710AHS Installation Instructions Manual

Ice machine with ride technology
Hide thumbs Also See for Horizon Elite HCD710AHS:
Table of Contents

Advertisement

2.

Site Preparation

Provide drainage, potable water supply and electrical power to within 6 feet (2 m) of ice
machine in accordance with local and national codes. Outdoor installation is not recommended
and will void warranty.
2.1

Installation site requirements

2 ft. x 1" OD
silicone tubing
Electrical
§ This appliance should be connected by a qualified person in accordance with applicable codes.
§ If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
H_C1010/1410(A/W)HS 208-230/60 breaker
* Requires a 15A dedicated circuit.
H_E1010/1410(A/W)HS 230/50
H_E710A, H_E1010A/W requires 15A dedicated circuit 1.50 mm
must be provided by end user and must conform to standard EN 60 335-2-24 of the end destination.
Potable Water Supply
10 psi to 70 psi (69 kpa to 483 kpa)
§ This equipment is to be installed with adequate backflow protection to comply with applicable federal, state, and
local codes
Condenser water supply for water-cooled systems
10 psi min.; 150 psi max. (69 kpa min.; 1034 kpa max.)
20 F to 90 F (–7 C to 32 C)
1.5 gallons (5.68 liters) per minute
Drains
3/4" Barb for silicone drain, 3/8" push-to-connect for chassis drain
Minimum 8" radius on silicone drain line. The drain line from the ice machine must have at least 1/4" per foot
(6,4 mm/0,3 m) pitch
HARMONY • RIDE Technology
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1" PVC Drain
(3/8" push-in connection, 3/8" OD tubing required)
Horizon Elite 710/1010/1410
3/8"
chassis
drain must
be used
115 V ±5%, 208 V –5% to 230 V +5%
WARNING!
H_D710AHS 115/60
Requires a 15A dedicated circuit.
H_E710AHS 230/50
wire, H_E1410A/W requires 20A dedicated circuit 4.00 mm
2
45 F to 90 F (7 C to 32 C)
(1/4" FPT inlet, 1/4" FPT outlet)
H_C1010
NEMA
6-15
H_D710
NEMA
5-15
H_C1410
NEMA
6-20
1/4" per foot
(6,4 mm per 0,3 m)
1'
wire. Plug
2
5

Advertisement

Table of Contents
loading

Table of Contents