C. Floor Protection
Parallel Installation:
Place the stove on a noncombustible type floor or floor
protector that extends a minimum of 6 inches (152mm) to
the front of the load door opening, 6 inches (152mm) to the
sides of the door opening, and 6 inches to the rear.
The P-Series does not require R value floor protection.
The minimum floor protector material is 20 gauge sheet metal.
Other floor protector materials that can be used include Type
I hearth pads, ceramic tile, stone, brick, etc. Figure 3.3
*Floor protection dimensions for the front and sides are
measured from the appliance door opening in The United
States. In Canada, the side dimension is measured from the
widest part of the appliance.
P43 - Minimum size rectangular floor protection is 25-7/16"
Wide by 26-3/4" Deep (646mm X 680mm).
P61A - Minimum size rectangular floor protection is 25-1/8"
Wide by 27-3/4" Deep (638mm X 705mm).
P68 - Minimum size rectangular floor protection is 25-3/16"
Wide by 27-3/4" Deep (640mm X 705mm).
Venting:
US -
Follow PL vent manufacturers recommendations when
configuring vent pipe installation.
Canada - Must extend 2" (51mm) beyond each side of any
horizontal flue pipe.
J
Figure 3.3

Floor Protection

Requirements
J Sides
K Front
L
Rear
10
L
F
loor protector
K
US
Canada
6"
152mm
6"
152mm
6"
152mm
Harman® • P-Series Installation Manual_R18 • 2014 - ___ • 06/18
Corner Installation:
Minimum size floor protection for a corner installation hearth
pad is:
P43 - Minimum size floor protection is 25-7/16" Wide by 26-
3/4" Deep (646mm X 680mm).
P61A - Minimum size floor protection is 25-1/8" Wide by 27-
3/4" Deep (638mm X 705mm).
P68 - Minimum size floor protection is 25-3/16" Wide by 27-
3/4" Deep (640mm X 705mm).
Note: Floor protector WILL NOT touch the wall using
minimum clearances.
If corner floor protection is desired to touch the wall, the
floor protection will need to be at least 40" x 40" (1016mm
x 1016mm). Note: This will allow the floor protection to
touch the wall as shown. Figure 3.4.
Alternate floor protector dimension may be used as long as
they satisfy the measurement requirements shown below.
Figure 3.4
D. Mobile Home Installation
When installing this unit in a mobile home, several
requirements must be followed:
1. The unit must be bolted to the floor. This can be done
using an appropriate fastener for the application.
2. The unit must also be connected to
"Termination Location and Vent Information" Section
3. Floor protection and clearances must be followed as
shown.
4.
The appliance must be properly grounded to the frame of
the mobile home using a minimum of 8 AWG copper solid
or stranded, insulated or bare wire or equivalent.
outside air. See
D.
3-90-436168i