Pressure Switch Testing & Replacement - Bradford White RG1PV50S Series Service Manual

Power vent gas water heaters
Hide thumbs Also See for RG1PV50S Series:
Table of Contents

Advertisement

PV Series
Step 15.
To resume operation, follow the instructions located on the lighting
instruction label or the lighting instructions located in the installation and
operation manual.
Pressure Switch Testing
Step 1.
Position power switch on gas
control to the "OFF" position.
Step 2.
Remove the three screws (Phillips screw driver) from control access cover
on blower assembly and remove cover (see photo 1).
Step 3.
Carefully remove pressure switch from blower housing (see photo 2).
20
20
WARNING
115 volt potential exposure. Use
caution to avoid personal injury.