Chapter 3
Chapter 3
Operation Setting and
Examples of I/O Adjustment
This chapter describes basic settings, frequency source
required for operation, examples of run command
source settings and examples of adjusted I/O terminals.
Basic settings 1
3.1 Set the load rating
Select [Ub-03] load specification selection on the
parameter setting screen.
STOP
Ub-03
Load type selection
00 V-Low Duty
01 Low Duty
02 Normal Duty
Menu
oFW
When [Ub-03] is changed, the parameters set for the
current are automatically adjusted in proportion to the
changed rated current, and the set values are changed.
If the current value is set as overload restriction,
electronic thermal and warning functions, those are to
be reconfirmed after changing this setting. Load
specification selection is to be set at first therefore.
Parameter
Parameter
Details
Select the load
[Ub-03]
specification.
*) The underlined value is set by default.
Operation Setting and Examples of I/O Adjustment
M1
H03
60.00
Option
Setting data
00: V-Low Duty (VLD)
01: Low Duty (LD)
02: Normal Duty (ND)
See "Chapter 4 Settings" for detailed operating
instructions
Basic settings 2
3.2 Set the motor data
Set the parameters listed in the table below on the
parameter setting screen according to the motor you
use (e.g. induction motor and permanent-magnet
motor).
STOP
AA121
Control mode_M1
0
VFC-VC
1
VFC-VP
2
VFC-FREE
3
VFC-A.bst
Menu
oFW
Parameter
Induction motor (IM)
Parameter
Details
[AA121]
Control pulse setting
[Hb102]
Capacity selection
[Hb103]
Motor poles setting
[Hb104]
Base frequency
[Hb105]
Maximum frequency
[Hb106]
Rated voltage
[Hb108]
Rated current
Synchronous motor (permanent-magnet motor)
(SM(PMM))
Parameter
Details
[AA121]
Control pulse setting
[Hd102]
Capacity selection
[Hd103]
Motor poles setting
[Hd104]
Base frequency
[Hd105]
Maximum frequency
[Hd106]
Rated voltage
[Hd108]
Rated current
Note: Motor constant setting is required for driving SM.
3-1
M1
H03
60.00
Option
Setting data
00: V/f control constant
torque characteristic , etc.
0.01 to 630.00 (kW)
2 to 48 (poles)
10.00 to 590.00 (Hz)
10.00 to 590.00 (Hz)
1 to 1000 (V)
0.01 to 9999.99 (A)
Setting data
09: PM motor
0.01 to 630.00 (kW)
2 to 48 (poles)
10.00 to 590.00 (Hz)
10.00 to 590.00 (Hz)
1 to 1000 (V)
0.01 to 9999.99 (A)