Electrical Data - Payne R95ESN Installation Instructions Manual

Single--stage, 35--in. (889 mm)tall high efficiency condensing gas furnace
Table of Contents

Advertisement

VOLTS---
FURNACE SIZE
HERTZ---
PHASE
0261410
115--- 60--- 1
0401410
115--- 60--- 1
0401712
115--- 60--- 1
0601412
115--- 60--- 1
0601714
115--- 60--- 1
0801716
115--- 60--- 1
0802120
115--- 60--- 1
1002120
115--- 60--- 1
1202420
115--- 60--- 1
1402422
115--- 60--- 1
* Permissible limits of the voltage range at which the unit operates satisfactorily.
# Unit ampacity = 125 percent of largest operating component's full load amps plus 100 percent of all other potential operating components' (EAC, humidifier,
etc.) full load amps.
Time ---delay type is recommended.
{
Length shown is as measured one way along wire path between furnace and service panel for maximum 2 percent voltage drop.
}
36
Fig. 36 - - Example of Single Stage Furnace Control
Table 11 – Electrical Data
OPERATING VOLTAGE
MAXIMUM
RANGE*
AMPS
Maximum*
Minimum*
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
127
104
Specifications subject to change without notice.
UNIT
UNIT
AMPACITY#
5.1
7.3
7
9.7
7.5
10.3
7.1
9.8
9.6
12.9
10
13.4
12.3
16.3
12.6
16.6
12.4
16.4
12.6
16.6
MINIMUM
MAXIMUM
MAXIMUM
WIRE
WIRE
FUSE OR CKT
SIZE
LENGTH
AWG
FT (M)}
14
50 (15.5)
14
38 (11.7)
14
36 (10.9)
14
38 (11.5)
14
28 (8.7)
14
27 (8.4)
12
35 (10.7)
12
34 (10.5)
12
35 (10.7)
12
34 (10.5)
440 01 6101 00
A190023
BKR
AMPS{
15
15
15
15
15
15
20
20
20
20

Advertisement

Table of Contents
loading

Table of Contents