Payne PG9MAA Specification

Multipoise condensing gas furnace
Hide thumbs Also See for PG9MAA:

Advertisement

Heating & Cooling
INSTALLATION
FLEXIBILITY:
CASING:
COMBUSTION
SYSTEM:
3-PASS
PRIMARY
HEAT
EXCHANGERS:
FLOW-THROUGH
SECONDARY
HEAT
EXCHANGERS:
LIMITED
WARRANTY:
MONOPORT
INSHOT
_
BURNERS:
®
/
FEATURES
The 4-way multipoise
design allows
a model
PG9MAA
to be installed
in an upflow, downflow,
or horizon-
tal
orientation.
Atl
sizes
of
the
PG9MAA
may be installed
in direct
vent (2-pipe)
applications.
All sizes
except
the
t40
size
may
be
installed
in non-direct
vent (1-pipe)
applications.
The
140
size
also
has an elevation
limitation
of 7,000
ft. See "Combustion
Air and Vent
Pipe" table for more information.
The casing
also has the required
openings
for
left-
or
right-side
connection
of gas,
electric,
drain,
and vent connections.
INTEGRATED
CONTROL
CENTER:
COMBUSTION
Enclosed
burner assembly
isolates
operating
noise without the expense
of sound deadening
devices.
This design
accelerates
heat trans-
fer and extracts
heat that conven-
tiona!
heat exchangers
waste
up
the
flue.
The
primary
heat
ex-
changer
is made
of aluminized
steel for corrosion
resistance.
AIR AND
VENTILATION:
Each cell is laminated
with our pa-
tented
polypropylene
for greater
corrosion
resistance
to help extend
the life of the furnace
for years
of
dependable
performance.
The heat
exchanger
is positioned
in the fur-
nace to extract additional
heat from
the combustion
products
regard-
less of furnace
orientation.
CERTIFICATIONS:
The PG9MAA
is backed
by a Life-
time
Warranty
on
the
heat
ex-
changers
in direct
vent application
(2O-year in non-direct
vent applica-
tions) and a 5-year Warranty
on al!
other parts.
Produce
precise
air-to-gas
mixture
which gives a clean burn. The large
monoport
on
the inshot
or injec-
QUALITY
REGISTRATION:
tion-type burners seldom, if ever,
needs cleaning.
The printed-circuit
board has con-
venient terminals which permit
quick-connection
of a thermostat,
air
conditioning
control circuits, a humid-
ifier, or an air cleaner.
The
control
has a built-in
status
indicator
and
self-test
feature.
A self-test
feature
allows for a complete
check of the
major components
in about 60 sec-
onds. The control
also features
an
adjustable
blower off delay.
The
PG9MAA
advanced
design
attows
Schedute
40
PVC,
Schedule
40 CPVC
pipe and fit-
tings,
PVC-DWV,
SDR-21
PVC,
SDR-26
PVC
(not
approved
in
Canada),
ABS-DWV,
or
ABS-
F628
Schedule
40 pipe
to bring
air
into
the furnace
for combus-
tion
and to be used
for venting
combustion
products
outside
the
structure.
The
vent
pipe can
ter-
minate
through
a
sidewall
or
through
the roof.
The
PG9MAA
units
are
CSA
(for-
medy
A.G.A.
and
C.G.A.)
design
certified for use with natural and pro-
pane
gases,
as
welt
as
GAMA
efficiency
rating
certified.
The
fur-
nace is factory-shipped
for use with
natural gas. A CSA (formerly
A.G.A.
and C.G.A.) listed gas conversion
kit
is required to convert fumace
for use
with
propane
gas.
The
model
PG9MAA
meets Catifomia
Air Qual-
ity
Management
District
emission
requirements.
The quality systems for this product
have
been
registered
by
UL
to
ISO 900I
Standards.
m
O
I,L!
or)
O
SS-PG9M-05

Advertisement

Table of Contents
loading

Summary of Contents for Payne PG9MAA

  • Page 1 C.G.A.) listed gas conversion less of furnace orientation. is required to convert fumace for use with propane gas. model LIMITED The PG9MAA is backed by a Life- PG9MAA meets Catifomia Air Qual- WARRANTY: time Warranty heat Management District...
  • Page 2: Dimensions

    261_® OUTLET _t _ _, TRAPLOCk'ON (OOWNFLOW & CONDENSATE DRAIN HORIZONTAL LEFT) '_t,,_. _otY_ A_CO,_ ," HO_I ONIA _<GH "h iN DJA e, T 2£ 5' VENT CONN 39 15' ACCI S80'RY ":9 pow,_ Nr[{Y "1 _ DP.AIN T,_AP OCATION DENS"_ZE (ALTERNATE "4...
  • Page 3 FRONT VIEW SIDE VIEW A93026 As an ENERGY STAR® MEETS DOE RESIDENTIAL CONSERVATION SERVICES partner, Payne Heating & PROGRAM STANDARDS. Cooling has determined that this product meets the ENERGY STAR® guidelines Before purchasing this appliance, read important for energy efficiency.
  • Page 4: Specifications

    Required for installation on combustible floors when no coil box is used, or when any coil box other than a Payne CD5, CK5 or KCAKC cased coil is used. 11-1 For direct vent applications only. N/A--Not Applicable. Unit is not allowed in this installation application.
  • Page 5 Required for installation on combustible floors when no coil box is used, or when any coil box other than a Payne CD5, CK5 or KCAKC cased coi! is used. 1-11- For direct vent applications only. N/A--Not Applicable. Unit is not allowed in this installation application.
  • Page 6 COMBUSTION-AIR AND VENT PIPING FOR DIRECT VENT (2 PIPE) APPLICATIONS MAXIMUM ALLOWABLE PIPE LENGTH (FT) PIPE ALTITUDE NUMBER OF 90 ° ELBOWS TERMINATION DIAMETER ABOVE UNIT SIZE TYPE (IN.)* LEVEL (FT) 024040 I-1/2 2 Pipe or 2-in. Concentric 036040 I-1/2 024060 036060 2 Pipe or 2-in.
  • Page 7 MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued ALTITUDE PIPE NUMBER OF 90 ° ELBOWS ABOVE SEA DIAMETER TERMINATION UNIT SIZE LEVEL (FT) TYPE (IN.)* 1-I/2 024040 2 Pipe or 2-in. Concentric 036040 024060 1-I/2 036060 2 Pipe or 2-in. Concentric 048060 036080 048080 2 Pipe or 2-in.
  • Page 8 MAXIMUM ALLOWABLE PIPE LENGTH (FT) Continued PIPE ALTITUDE NUMBER OF 90 ° ELBOWS TERMINATION DIAMETER ABOVE UNIT SIZE TYPE (IN.)* LEVEL (FT) I-1/2 024040 2 Pipe or 2-In. Concentric 036040 024060 I-1/2 036060 2 Pipe or 2-In. Concentric 048060 036080 048080 2 Pipe or 2-In.
  • Page 9 MAXIMUM ALLOWABLE EXPOSED VENT PIPE LENGTH (FT) WITHOUT INSULATION IN WINTER DESIGN TEMPERATURE AMBIENT FOR DIRECT-VENT APPLICATIONS* WINTER DESIGN MAXIMUM PIPE WITH 3/8-1N. OR UNIT TEMPERATURE DIAMETER WITHOUT THICKER INSULATIONt SIZE (°F) (IN.) INSULATION I-I/2 I-I/2 I-I/2 2-I/2 2-I/2 2-I/2 2-I/2 2-I/2 2-I/2...
  • Page 10 VENT PIPING FOR NON-DIRECT VENT (1 PIPE) APPLICATIONS MAXIMUM ALLOWABLE VENT PIPE LENGTH (FT) VENT PIPE ALTITUDE NUMBER OF 90 ° ELBOWS DIAMETER ABOVE UNIT SIZE (IN.)* LEVEL (FT) 024040 1-1/2 036040 1-1/2 024060 036060 048060 1-1/2 036080 048080 0 to 2000 060080 2-1/2 048100...
  • Page 11 MAXIMUM ALLOWABLE VENT PIPE LENGTH (FT) Continued VENT PIPE ALTITUDE NUMBER OF 90 ° ELBOWS DIAMETER ABOVE UNIT SIZE (IN.)* LEVEL (FT) I-I/2 024040 036040 024060 I-I/2 036060 048060 036080 5001 to 60001- 048080 060080 2-I/2 2-I/2 048100 060100 31-no disk 060120 41-no disk I-I/2...
  • Page 12 COMBUSTION-AIR PIPEFORNON-DIRECT VENT APPLICATIONS (Sizes 040 through 120 only) ._ FIELD-SUPPLIED 2-IN. DIAMETER FIELD-SUPPLIED PVC 90' ELBOW// 2-IN. DIAMETER U-FA- _" PIPE LENGTH OF STRAIGHT PIPE PORTION OF COMBUSTION-AIR INLET PIPE ASSEMBLY (IN.) CASING WIDTH 17-1/2 8-1/2 + 1/2 10-I/2 + I/2 24-1/2 12 + 1/2...
  • Page 13 ACCESSORIES (Continued) SIDE FILTER RACK* A80199 *Accepts one 16 x 25 x 1 in. filter. ACCESSORY DOWNFLOW SUBBASE 114"TYP OPENING FACTORY-SUPPLIED. FIELD-INSTALLED INSULATION A88207 A97427 Disassembled Assembled FURNACE HOLE FLOOR OPENING PLENUM OPENING* CASING FOR WIDTH WIDTH FURNACE IN DOWNFLOW APPLICATION ADJUSTMENT Furnace with or without CD5, CK5 Coil 17-I/2...
  • Page 14 CLEARANCE T OCOMBUSTIBLES • This forced air fumace is equipped for use with naturaU gas at amtitudes 0 - 10,000 ft (0 m3,050m), except t40 size furnaces are onUy approved for aUtitudes 0 - 7,000 ft. (0 _ 2,135m). An accessory kit, suppJ_ed by the manufacturer, shah be used to convert toprepene gas use or may be required for some naturaU gas appUicetions.
  • Page 15 AIR DELIVERyICFM (With Filter)* EXTERNAL STATIC PRESSURE (In. wc) RETURN-AIR UNIT SIZE SUPPLY SPEED 1 side High 1075 I040 024040 Med-Low bottom High 1470 I4 I5 I400 1285 1215 1120 1 side Med-High 1315 I280 I235 1180 1115 I035 036040 Med-Low 1 I25 11 t0...
  • Page 16 SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: SS-PG9M-04 1 lcating& Cooling --16-- © 2004 Payne Heating & Cooling 7310 West Morris Street. Indianapolis, IN 46231 PRINTED IN U.S.A. Catalog No 52PG-9M5 9-04...

Table of Contents