SECTION 2: CIRCUIT REQUIREMENTS
Model G9862
The Model G9862 Shaper is prewired with a 5
H.P. single-phase motor. Under normal use, the
motor draws approximately 30 amps at 220V. We
recommend using a 30 amp circuit. This includes
the appropriate wiring and circuit breaker. If fre-
quent circuit failure occurs when using the
shaper, contact our service department.
The shaper must be connected to its own dedi-
cated 30A circuit. It should not share a circuit with
any other machine. A standard 2-pole breaker is
necessary for use with the shaper.
We recommend using a NEMA-style L6-30 plug
and outlet similar to that in Figure 1. You may
also "hard-wire" the shaper directly to your panel,
provided you place a disconnect near the
machine. Check the electrical codes in your area
for specifics on wiring requirements.
Figure 1. Recommended plug configuration for
220V, three-phase operation.
G9862/G9968 Shaper
Model G9968
The Model G9968 Shaper is prewired with a 7
H.P. three-phase motor. Under normal use, the
motor draws approximately 20 amps at 220V. We
recommend using a 20 amp circuit. This includes
the appropriate wiring and circuit breaker. If fre-
quent circuit failure occurs when using the
shaper, contact our service department.
The shaper must be connected to its own dedi-
cated 20A circuit. It should not share a circuit with
any other machine. A standard 3-pole breaker is
necessary for use with the shaper.
We recommend using a NEMA-style L15-30 plug
and outlet similar to that in Figure 1. You may
also "hard-wire" the shaper directly to your panel,
provided you place a disconnect near the
machine. Check the electrical codes in your area
for specifics on wiring requirements.
Figure 1. Recommended plug configuration for
220V, three-phase operation.