Crosley CAME28B2 Use & Care Manual page 12

Advertisement

INSTALLATION INSTRUCTIONS
B.Thru-The-Wall Installation
NOTE: Consult local building codes prior to
installation, or a qualified carpenter.
1
Select Wall Location
The air conditioner has a slide-out chassis, so
that it can be installed through an outside wall
as specified below:
Max. Wall thickness: 12
IMPORTANT: Side louvers must never be blocked.
NOTE: All parts needed for Thru-The-Wall Install-
tion are provided, except a wood frame, shims,
and 10 wood screws(#10-1 long minimum).
Select a wall surface that:
1. does not support major structural loads such
as the frame construction at ends of windows,
and under truss-bearing points, etc.
2. does not have plumbing or wiring inside.
3. is near existing electrical outlets, or where
another outlet can be installed.
4. faces, and is not blocked to the area to be
cooled.
5. allows unblocked airflow from rear sides and
end(outside) of installed air conditioner.
2
Prepare Wall
1. Prepare wall in frame construction (including
brick and stucco veneer). Working from inside
the room, find wall stud nearest the center of
area where air conditioner will be installed
(by sounding wall, or by magnetically finding
nails).
2. Cut or knock out a hole on each side of center stud.
3. Measure between inside edges of every other
stud as shown in Fig.1.
3-3/8" MIN
(8.6 cm)
Carefully measure and cut an opening with the
following dimensions depending on your model.
See Fig.1 and Fig.2.
WIDTH X = inside model width plus twice the
thickness of framing material used.
HEIGHT Y =inside model height plus twice the
thickness of framing material used.
or
10
Fig.1
Inside Frame Height: 18-7/8"(47.9cm) or18" (45.7cm)
Inside Frame Width: 26-3/4"(67.9cm) or 23-7/8"(60.6cm)
Y
Inside
Frame
Height
4. Build a wooden frame with the INSIDE dimen-
sions of your model listed above. (Measure
twice remember). Frame depth should be the
same as wall thickness. Fill in the space from
the opening to the studs with wood spacers,
as shown.
5. Nail frame to spacers to spacers with front
flush with drywall.
LEVEL
NOTE: If wall thickness is 8-1/2 or more, add
aluminum flashing over bottom of frame opening
to assure no water can enter area between inner
and outer wall.
Aluminum Flashing
Over Bottom Of Frame
10
Inside
Frame
Width
Up to 8-1/2"
Fg.2
NAIL SPACERS
TO STUDS
Fig.3
Caulkas
Required
Fig.4
Over
8-1/2