Summary of Contents for Crosley CATHE18A2

  • Page 1 CATHE18A2...
  • Page 3 INTRODUCTION IMPORTANT SAFETY INSTRUCTION ................ELECTRICAL REQUIREMENTS ................... PACKING LIST ......................INSTALLATION&ASSEMBLY INSTRUCTIONS .............. USING YOUR AIR CONDITIONER ................OPERATING YOUR AIR CONDITIONER ................ CARE AND CLEANING ....................TROUBLESHOOTING ....................
  • Page 5 18K/22K/24K...
  • Page 6 5/16" Long Hex-head Screw 5/8" Long Hex-head Screw 1/2" Long Hex-head Screw 5/8" Long Flat Head Bolt and Locknut Sill Angel Bracket 1/2" Long Flat Head Bolt and Locknut Gasket (Only for E-star model) Support Bracket(with R and L remark)
  • Page 7 15K/18K 22K/24K 17.91 18.625 23.625 26.50 19.00 19.50 28.00 30.00 41.00 41.00...
  • Page 8 (15K/18K See FIG.1/FIG.2 ; 22K/24K See FIG.3/FIG.4). FIG.1 FIG.2 SASH SASH 19 MIN 1/2 MIN 1/2 MIN 19 MIN 1/2 MIN Storm Window Frame or Obstruction Storm Window Frame or Obstruction FIG.3 FIG.4 SASH SASH 19 1/2 MIN 1/2 MIN 1/2 MIN 19 1/2 MIN 1/2 MIN...
  • Page 9 FIG.5 FIG.6 FIG.5 FIG.6 FIG.7 & 8 FIG.9 FIG.9 FIG.7 FIG.8...
  • Page 10 6.Remove the six screws from the cabinet.(Every side for top,left and right has two screws.) (FIG.10) FIG.10 FIG.11 FIG.11 8.Take the pearl cotton for 24K(FIG.12). FIG.12...
  • Page 11 FIG.13a FIG.13a 5/16 Long Hex-head Screw FIG.13b- FIG.13b 5/16" Long Hex-head Screw FIG.14 (Suggest to keep a downward oblique, to let accumulated rain water to drain out, from back side of the unit bottom.)
  • Page 12 Long Flat head Bolt and Locknut 5/8" Long Flat Head Bolt (It should set on the gasket for 22K/24K) Long Flat head Bolt and Locknut 5/8" Long Hex-head Screw Gasket 5/8" Long Hex-head Screw 1/2" Long Hex-head Screw...
  • Page 13 sash lock Sash Lock 5/8" Long Hex-head Screw FIG.15...
  • Page 14 15K/18K 22K/24K 18 1/4 (46.4 cm) 19 1/2 (49.5 cm) 23 7/8 (60.6 cm) 26 9/10 (68.3 cm) FIG.16 (Page 6 and 7) FIG.17 FIG.18...
  • Page 15 FIG.19 FIG.20...
  • Page 16 Cool Mode: The cooling function allows the air conditioner to cool the room and at the same time reduces air humidity . Press the MODE button to activate the cooling function. To optimi z e the function of the air conditioner, adjust the For Cooling model temperature and the speed by pressing the button indicated.
  • Page 17 6. ECO Button: When the unit is in ECO mode, the Directional Louvers: To direct the airflow, use the light will turn on. In ECO mode, the unit will turn-off horizontal wheel to control the horizontal direction once the room is cooled to the user set temperature. and the air deflector to control the vertical The unit will turn back on when the room temperat- direction.
  • Page 18 5. Timer: Use these buttons on the control panel and remote to set the Timer. Timer Off: The timed stop is programmed by pressing TIMER button. Set the rest time by pressing the button until the rest time displayed is to your demand then press TIMER button again.
  • Page 19 FIG.21 FIG.21...
  • Page 24 CrosleyCare servicer. For one year from your original date of purchase, Crosley will pay all costs for repairing or replacing any parts of this appliance that prove to be defective in materials or workmanship when such appliance is installed, used and maintained in accordance with the provided instructions.