Installation - Scotsman F1322L Installation And User Manual

Remote low side modular flaked and nugget ice machines
Table of Contents

Advertisement

N0922L, N1322L, F1222L, F1522L
D Series Remote Low Side User Manual

Installation:

This machine is designed to be used indoors, in a
controlled environment. Operation outside the limits
listed here will void the warranty.
Air temperature limits
Minimum
Ice maker
50
F.
o
Water temperature limits
Minimum
All models
40
F.
o
Water pressure limits (potable)
Minimum
All models
20 psi
Voltage limits
Minimum
115 volt
104
Minimum conductivity (RO water)
• 10 microSiemens / CM
Water Quality (ice making circuit)
• Potable
The quality of the water supplied to the ice machine
will have an impact on the time between cleanings
and ultimately on the life of the product. Water can
contain impurities either in suspension or in solution.
Suspended solids can be filtered out. In solution
or dissolved solids cannot be filtered, they must be
diluted or treated. Water filters are recommended
to remove suspended solids. Some filters have
treatment in them for suspended solids. Check with a
water treatment service for a recommendation.
RO water. This machine can be supplied with Reverse
Osmosis water, but the water conductivity must be no
less than 10 microSiemens/cm.
Potential for Airborne Contamination
Installing an ice machine near a source of yeast
or similar material can result in the need for more
frequent sanitation cleanings due to the tendency of
these materials to contaminate the machine.
Most water filters remove chlorine from the water
supply to the machine which contributes to this
situation. Testing has shown that using a filter that
does not remove chlorine, such as the Scotsman
Aqua Patrol, will greatly improve this situation.
Maximum
Warranty Information
100
F.
o
The warranty statement for this product is provided
separately from this manual. Refer to it for applicable
coverage. In general warranty covers defects
in material or workmanship. It does not cover
Maximum
maintenance, corrections to installations, or situations
100
F.
o
when the machine is operated in circumstances that
exceed the limitations printed above.
Maximum
80 psi
Maximum
126
October 2014
Page 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

F1222lProdigy plus d seriesN0922lN1322l

Table of Contents