14.2 Remote Control Button
14.2.1
SET Button
•
To check current remote control transmission code and store the transmission code to EEPROM:
Press "Set" button continuously for 10 seconds by using pointer.
o
Press "Timer Set" button until a "beep" sound is heard as confirmation of transmission code change.
o
•
To change the air quality sensor:
Press and release by using pointer
o
Press the Timer Decrement button to select sensitivity:
o
1. Low sensitivity
2. Standard (Default)
3. Hi sensitivity
Confirm setting by pressing Timer Set button, a "beep" sound will be heard. LCD returns to original display
o
after 2 seconds.
LCD returns to original display if remote control does not operate for 30 seconds.
o
14.2.2
RESET (RC)
•
To clear and restore the remote control setting to factory default.
Press once to clear the memory
o
14.2.3
TIMER
•
To change indoor unit indicators' intensity:
Press continuously for 5 seconds.
o
14.2.4
TIMER
•
To change remote control display from Degree Celsius (°C) to Degree Fahrenheit (°F)
Press continuously for 10 seconds.
o
93