14.2 Select Remote Control Transmission Code
•
There are 4 types of remote control transmission code could be selected and stored in EEPROM of indoor unit.
The indoor unit will only operate when received signal with same transmission code from remote control. This
could prevent signal interference when there are 2 or more indoor units installed nearby together.
•
To change remote control transmission code, short or open jumpers at the remote control printed circuit board.
14.3 Remote Control Button
14.3.1 SET Button
•
To check remote control transmission code:
Press for more than 10 seconds by using pointer
o
•
To change the air quality sensor:
Press and release by using pointer
o
Press the Timer Decrement button to select sensitivity:
o
1. Low sensitivity
2. Standard (Default)
3. Hi sensitivity
Confirm setting by pressing Timer Set button, a "beep" sound will be heard. LCD returns to original display
o
after 2 seconds.
LCD returns to original display if remote control does not operate for 30 seconds.
o
14.3.2 CLOCK Button
•
To change the remote control time format:
Press for more than 10 seconds
o
14.3.3 RESET (RC) Button
•
To clear and restore the remote control setting to factory default.
Press once to clear the memory
o
14.3.4 RESET (AC) Button
•
To restore the unit's setting to factory default.
Press once to restore the unit's setting.
o
14.3.5 TIMER ▲
•
To change indoor unit indicators' intensity:
Press continuously for 10 seconds.
o
14.3.6 TIMER ▼
•
To change remote control display from Degree Celsius (°C) to Degree Fahrenheit (°F)
Press continuously for 10 seconds.
o
J - A
J - B
J_B
PbF
UR79PB1606A
Remote Control Printed Circuit Board
Jumper A (J-A)
Jumper B (J-B)
Short
Open
Open
Open
Short
Short
Open
Short
53
Remote Control No.
A (Default)
B
C
D