12.8 Horizontal Airflow Direction Control

For CS-A9KKD-2 and CS-A12KKD-2, the horizontal airflow direction louver can be adjusted manually by hand.
For CS-A18KKD-2, CS-A24KKD-2 and CS-A28KKD-2, the horizontal airflow direction louver are as following.
12.8.1 Auto Control
When the horizontal airflow direction is set to Auto using the remote control, the vanes swings left and right for
Cooling and Soft Dry (0°-44°), Heating (8°-36°) as shown in the diagram.
When stopped with remote control, the discharge vane is reset, and stop at the reset position.
During Cooling operation or Soft Dry operation, indoor fan motor may stop to rotate at certain periods. At that
condition, the vane will stop swinging and rest at 22° angle.
During Heating operation, the piping air temperature reaches 38°C, the vanes swings left and right. When the
piping air temperature falls to 35°C, the vanes will stop swing and rest at 22°.
12.8.2 Manual Control
When the horizontal airflow direction is set to Manual using the remote control, the automatic airflow is released
and the airflow direction vane move left and right in the range shown in the diagram.
The louver can be adjusted by pressing the button to the desired vane position.
When stopped with remote control, the vanes is reset and stopped at reset position.
Closing
position
/ 148°
Closing
position
/ 133°
Horizontal
Upper limit / 0°
17°
Upper limit for
heating mode
24°
34°
43°
52°
Lower limit for heating mode
Horizontal
Upper limit / 0°
17°
Upper limit for
heating mode
24°
34°
43°
52°
Lower limit for heating mode
65