Periodic Pressure Relief Valve Check

Test the crimping tool periodically to ensure that the
pressure relief valve activates at the proper pressure.
Testing the Crimping Tool
1. Center a test slug between the nibs.
2. Pull the trigger to advance the nibs. Hold the trigger
down until the pressure relief valve activates.
3. After achieving pressure relief, the ram will auto-
matically return to the start position and the nibs will
retract.
4. Evaluate the test slug as follows:
• If the test slug does not fit into GO slot, the
pressure relief valve is set too high. Send the
crimping tool to an authorized Greenlee service
center.
• If the test slug fits into the GO slot, the pressure
relief valve is set correctly.
• If the test slug fits into the NO GO slot, the
pressure relief valve is set too low. Send the
crimping tool to an authorized Greenlee service
center.
GO
NO GO
Greenlee Textron / Subsidiary of Textron Inc.
EK06AT and EK06ATC

Maintenance

1. Inspect nibs for wear or damage such as cracks,
gouges or chips.
2. Inspect the crimping tool for damage or leaks. Have
a damaged or leaking crimping tool repaired at an
authorized Greenlee service center.
After Each Use
Do not use solvents or flammable
liquids to clean the crimping tool.
Solvents or flammable liquids could
ignite and cause serious injury or
property damage.
1. Wipe all tool surfaces clean with a damp cloth and
mild detergent.
2. Fully retract and lock the trigger. Place the crimping
tool in the carrying case. Store in a cool, dry place.
3. Charge the battery.
Monthly
1. Thoroughly clean all surfaces.
2. Check the oil level.
Annually or Every 10,000 Crimps
1. Change the hydraulic oil.
2. Return the tool to an authorized Greenlee service
center for inspection.
Checking the Oil Level
1. Remove the two screws (215) that retain the tank
housing cover.
2. Remove the tank housing cover (214).
3. Point the crimping head downward and remove the
oil plug (16). Add oil if necessary.
4. Replace the oil plug and the tank housing cover.
Secure with screws.
Recommended Hydraulic Oils
AVIA HVI 15
Shell Tellus T-15
Mobil DTE 11
NUTO H 15