Maintenance (cont'd)
Electrical Control Unit Removal
Disconnect power supply before
servicing bender. Servicing to be done
only by trained service technician.
Failure to observe this warning could
result in severe injury or death.
1. Remove the cover retained by ten 5/16" hex screws.
2. Disconnect the pendant switch plug from the circuit
board and remove through the cord grip.
3. Remove two hex mounting screws, one on each
side.
3/8" Hex
Mounting
Screw
Greenlee / A Textron Company
555
4. Remove the motor leads, power cord ground wire,
and neutral wire before the control unit can be totally
removed from the bender.
Motor Leads
Ground Wire
Electrical control removed from bender