Sharp AF-S80CX Service Manual page 23

Hide thumbs Also See for AF-S80CX:
Table of Contents

Advertisement

6. Safety start
When you turn the air conditioner OFF and restart again soon, wait at least 3 minutes before the cooling operation
starts.
7. Test mode
Keep pushing both buttons "POWER ON/OFF" and " " " and supply the power, the system will go to the test mode.
In this mode, the output operation is switched by pushing buttons. Normal outputs are shown in Table Y-2.
For selfdiagnosis check mode
No. PUSH KEY (SWITCH)
PLUG IN the power supply cord
0
while pushing power ON/OFF
key and
(down) key.
1
SELECTOR <SW3>
2
<SW6>
3
<SW5>
4
TIMER
<SW2>
5
ENERGY SAVER
<SW1>
6
ON/OFF
<SW4>
7
POWER ON/OFF by REMOTE CONTROL
8
POWER SUPPLY OFF
1) If thermistor is normal (nether short nor open), LED is ON.
2) When A/D (R42) bit 7 = 1, LED is ON.
2) When A/D (R42) bit 6 = 1, LED is ON.
2) When A/D (R42) bit 5 = 1, LED is ON.
T(˚C)
T(˚F)
0
32.0
1
33.8
2
35.6
3
37.4
4
39.2
5
41.0
6
42.8
7
44.6
8
46.4
9
48.2
10
50.0
11
51.8
12
53.6
13
55.4
14
57.2
15
59.0
16
60.8
17
62.8
18
64.4
19
66.2
20
68.0
V ....... Input the voltage of microcomputer (No. 10-port).
Table Y-2
BEPP
LED1
SOUND
FAN
FAN
HIGH
MID
<LED2>
<LED3>
<LED4>
2
8.8
ON
ON
1
OFF
OFF
OFF
1
01
OFF
OFF
2)
3)
1
02
ON
OFF
1
03
OFF
ON
1
04
OFF
OFF
1
05
ON
OFF
1
05
OFF
OFF
OFF
OFF
OFF
Table Y-3
R(kΩ)
V(volts)
49.33
1.17
46.86
1.21
44.53
1.26
42.33
1.31
40.25
1.36
38.29
1.41
36.44
1.46
34.68
1.51
33.02
1.56
31.45
1.61
29.96
1.67
28.55
1.72
27.22
1.78
25.96
1.83
24.76
1.89
23.62
1.94
22.56
2.00
21.52
2.05
20.55
2.11
19.63
2.17
18.76
2.22
LED LIGHTING
COOL
FAN
TIMER
FAN
ENERGY
LOW
<LED9>
<LED5>
<LED7>
SAVER
<LED8>
ON
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
4)
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
T(˚C)
T(˚F)
21
69.8
22
71.6
23
73.4
24
75.2
25
77.0
26
78.8
27
80.6
28
82.4
29
84.2
30
86.0
31
87.8
32
89.6
33
91.4
34
93.2
35
95.0
36
96.8
37
98.6
38
100.4
39
102.2
40
104.0
23
AF-S80CX
CHECK ITEM
and REMARK
POWER
FAN
COMP
ON/OFF
OUTPUT
OUTPUT
<LED6>
ON
OFF
O F F
LED ALL ON
OFF
LOW
O F F
LED ALL OFF
1)
MIDDLE
O F F
OFF
HIGH
O F F
FAN CHECK
ON
OFF
O F F
OFF
LOW
O F F
OFF
HIGH
O N
COMPRESSOR CHECK
OFF
MIDDLE
O F F
REMOTE CONTROL CHECK
OFF
OFF
O F F
R(kΩ)
V(volts)
17.93
2.28
17.14
2.33
16.39
2.39
15.68
2.44
15.00
2.50
14.36
2.55
13.74
2.61
13.16
2.66
12.60
2.71
12.07
2.77
11.57
2.82
11.09
2.87
10.63
2.93
10.19
2.98
9.78
3.03
9.38
3.08
9.00
3.13
8.64
3.17
8.30
3.22
7.97
3.27

Advertisement