AF-S80CX
17. Unscrew the 1 screw holding the centrifugal fan.
1. Unscrew the 1 screw holding the control box cover.
CAUTION: DISCHARGE THE FAN MOTOR CAPACITOR
AND RUNNING CAPACITOR BEFORE
TOUCHING THOSE CAPACITORS OR OTHER
COMPONENTS OR WIRING.
2. Unscrew the 3 screws holding the printed wiring board.
3. Cut the wire fixing bands holding the fan motor lead
wires, the compressor cord and the power supply cord.
DISASSEMBLING THE CONTROL BOX
18. Unscrew the 3 screws holding fan motor.
4. Unscrew the 1 power supply cord grounding screw.
Unscrew the earth screw. Unscrew the 1 screw holding
the capacitor clamp and the fan motor capacitor.
5. Detach each connector by using long-noise pliers.
6. Unscrews the 2 screws holding the transformer and
remove the control board with unhooking the 2 spacers.