TROUBLESHOOTING CHART (CONTINUED)
LED Status
Six flashes and three
second pause.
Seven flashes and three
second pause.
Eight flashes and three
second pause
Control Status
Water leak detected by
accessory module (some
models).
Gas valve electronic fault
detected.
False pilot flame present.
27
Probable Cause
Excessive amount of water in drain
pan/water dam.
1.
Verify control is not wet or
physically damaged.
2.
Turn set point knob to "OFF"
position. Turn set point knob
to "PILOT" position and light
pilot.
3.
Replace gas valve if seven
flash error persists.
1.
Pilot valve stuck in open
position
2.
Turn set point knob to "OFF"
position. Turn set point knob to
"PILOT" position and light pilot.
3.
Replace gas valve if eight flash
error persists.