Thermostat Adjustment - Bradford White RG250T6N Manual

Gas-fired water heater
Hide thumbs Also See for RG250T6N:
Table of Contents

Advertisement

THERMOSTAT ADJUSTMENT - White Rodgers gas control.
160°F Control
The thermostat dial is set to its lowest temperature setting when shipped from the factory.
Remember that lower temperature settings are more energy efficient. Adjust the
temperature by turning the thermostat dial. It is suggested that the starting point setting not be
greater than the "
indicated above. Rotate the thermostat dial clockwise
setting. Rotate the thermostat dial counter-clockwise
setting. Adjust the dial until the minimum acceptable temperature is achieved (See figure 2
above for approximate temperature settings).
Robertshaw gas control.
160°F Control
The thermostat dial is set to its lowest temperature setting when shipped from the factory.
Remember that lower temperature settings are more energy efficient. Adjust the
temperature by turning the thermostat dial. It is suggested that the starting point setting not be
greater than the " " mark on the thermostat dial (approximately 120°F [48.9°C]) as indicated
above. Rotate the thermostat dial counter-clockwise
setting. Rotate the thermostat dial clockwise
Adjust the dial until the minimum acceptable temperature is achieved (See figure 3 above for
approximate temperature settings).
" or "
" mark on the thermostat dial (approximately 120°F [48.9°C]) as
180°F Control
Figure 2
180°F Control
Figure 3
to increase the temperature setting.
20
to decrease the temperature
to increase the temperature
to decrease the temperature

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rg250t6n-394Rg240t6xRg240s6xUrg250t6n

Table of Contents