Adjustment - Kenwood TK-3501 Service Manual

Hide thumbs Also See for TK-3501:
Table of Contents

Advertisement

TK-3501
Test Equipment Required for Alignment
Test Equipment
1.
Standard Signal Generator (SSG)
2.
RF Power Meter
3.
Deviation Meter
4.
Digital Volt Meter (DVM)
5.
Oscilloscope
6.
High Sensitivity
Frequency Counter
7.
DC Ammeter
8.
AF Volt Meter (AF VM)
9.
Audio Generator (AG)
10. Distortion Meter
11. Spectrum Analyzer
12. Tracking Generator
13. 8Ω Dummy Load
14. Regulated Power Supply
■ DC Supply
BATT+, BATT– : External power supply terminal (Fasten
it with an alligator clip.)
18

ADJUSTMENT

Frequency Range
Modulation
Output
Input Impedance
Operation Frequency
Measurement Range
Frequency Range
Measuring Range
Input Impedance
Frequency Range
Frequency Stability
Frequency Range
Voltage Range
Frequency Range
Output
Capability
Input Level
Measuring Range
Center frequency
Output Voltage
BATT+ (7.5V)
– +
BATT– (GND)
Major Specifications
400 to 520MHz
Frequency modulation and external modulation
–127dBm/0.1µV to greater than –47dBm/1mV
50Ω
400 to 520MHz
Vicinity of 10W
400 to 520MHz
10mV to 10V DC
High input impedance for minimum circuit loading
DC through 30MHz
10Hz to 1000MHz
0.2ppm or less
5A
50Hz to 10kHz
1mV to 10V
50Hz to 5kHz or more
0 to 1V
3% or less at 1kHz
50mV to 10Vrms
10kHz to 1GHz or more
50kHz to 600MHz
100mV or more
Approx. 8Ω, 3W
5V to 10V, approx. 3A
Useful if ammeter equipped

Advertisement

Table of Contents
loading

Table of Contents