Operator Panel Button Service Check - Lexmark 4500-00 Series Service Manual

Table of Contents

Advertisement

4500

Operator panel button service check

FRU
Operator panel
Operator panel cable
2-78
Service Manual
Action
Open controller card cage and
locate the connection for the
operator panel (J2 for E320/E322 or
J18 for E220/E321/E323).
Check for continuity between pins 1
and 2 as you press the button (or
Continue button E220/E321/E323).
Similarly, check the continuity
between pins 1 and 6 while pressing
Cancel (E220/E321/E323).
• If continuity is not present, replace
the operator panel.
Note: Check margin alignments
after replacing the operator
panel assembly. See
"Printhead assembly " on
page 4-2
(steps 1through 11)
for more information. If
margin errors are
unacceptable, corrections
can only be made through
software. Contact the next
level of support or Lexmark at
1–800–539–6275.

Advertisement

Table of Contents
loading