Specifications; Safety And Regulatory Compliance - Omega Engineering SP-001 User Manual

Ultra miniature ir smart probe
Table of Contents

Advertisement

Specifications

General Specifications
Measured Temperature Range:
Accuracy @ Ambient of 0-50°C (32 to 122°F):
Accuracy Over Entire Ambient Operating Range:
Repeatability:
Field of View:
Spectral Response:
Emissivity:
Response Time:
Outputs:
Power:
Operating Temperature:
Housing:
Dimensions:
Weight:

Safety and Regulatory Compliance

CE:
The product herewith complies with the essential requirements and other relevant provisions of the EMC Directive
2014/30/EU, and the Low Voltage Directive 2014/35/EU, and carries the CE-marking accordingly
The following CE Mark
The CE declaration is available at the website listed on the cover page of this manual.
Vibration Test
Frequency Range
Acceleration
Duration
Sweep
is affixed to this equipment.
-70 to +380°C (-94 to 716°F)
1°C (1.8°F) or 1% of reading, whichever is greater
4°C (3.6 °F) or 3% of reading, whichever is greater
1°C (1.8°F) or 1% of reading
SP-001 is 6:1
SP-002 is 10:1
5.5 to 14 microns
0.01 to 1.00, software adjustable
30 to 1500 msec, adjustable
2x Open Drain 100 mA max
3.3 Vdc, 0.05 W max
-40 to 85°C (-40 to 185°F) less than 95% RH, non-condensing
Stainless steel, IP 67 (NEMA 6)
12 OD x 114 mm L (0.47" x 4.49")
35 g (1.2 oz)
10 Hz to 500 Hz
10 g
45 min per axis
1 octave/min