Parts and their functions
G/L IN connector [G/L IN]
v
This is the external sync signal input connector.
This unit supports BBS (Black Burst Sync) and tri-level
synchronization.
External synchronization (genlock) can be applied to
achieve phase alignment when multiple cameras are to
be used or when the unit is to be used in combination with
other devices.
Supply to this connector the sync signals that correspond
to the video signal format which has been set.
External sync signal input format
Format
1080/59.94p
480/59.94i
1080/29.97p
480/59.94i
1080/59.94i
480/59.94i
1080/29.97PsF
480/59.94i
720/59.94p
480/59.94i
1080/50p
576/50i
1080/25p
576/50i
1080/50i
576/50i
1080/25PsF
576/50i
720/50p
576/50i
● External synchronization is performed using the SDI video
signal. Synchronization is not possible using the HDMI video
signal or the IP video signal.
For horizontal phase adjustment, refer to "Genlock screen"
(page 44) in <Operations and Settings>.
Service switches
w
SW1
SW2 SW3 SW4
ON
OFF
Function
SW1 Camera
address setting
See descriptions for SW1 to
SW2
(standard serial
SW3
SW3
communication)
Panasonic
Communication
proprietary
SW4
format
serial
communication
Always leave at OFF (used for factory
SW5
adjustments)
SW6 Infrared output Disable
Communication
SW7
9600 bps
baud rate
Communication
SW8
RS-422
connector
Notes
● Perform switch settings before turning the unit on.
● Cameras whose camera address setting switches
are set to AUTO cannot coexist with cameras whose
switches are set to 1 to 7.
● Manually setting multiple cameras to the same
address will not allow you to control multiple
cameras from a single controller simultaneously.
42
(continued)
BBS
Tri‑level sync
1080/59.94i
1080/59.94i
1080/59.94i
720/59.94p
1080/50i
1080/50i
1080/50i
720/50p
SW5 SW6 SW7 SW8
Factory
OFF
ON
Standard serial
communication
Enable
38400 bps
RS-232C
Service switch settings
(1) SW1 to SW3: Camera address setting switches
Configure the camera address.
Set this to AUTO under normal circumstances. When
cameras are set to AUTO, addresses will be assigned to
the cameras automatically in response operation from
the controller in the order in which the cameras were
connected.
To manually configure the address, set the switches as
follows.
Address
SW1
SW2
SW3
(2) SW4: Communication format selection switch
Selects the communication format.
When this is set to ON, standard serial communication is
enabled.
When this is set to OFF, Panasonic's proprietary serial
communication is enabled.
(3) SW5: Maintenance switch
Fixed at OFF.
Do not change this switch setting.
(4) SW6: Infrared output switch
When this is set to ON, infrared output is enabled. The
signal received via the remote control sensor is output
from pins 7 and 8 of the RS-232C IN connector.
Signal output is disabled when this is set to OFF.
(5) SW7: Communication baud rate switch
When this is set to ON, the baud rate is 38400 bps.
When this is set to OFF, the baud rate is 9600 bps.
(6) SW8: Communication connector switch
When this is set to ON, RS-232C is enabled.
When this is set to OFF, RS-422 is enabled.
setting
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
AUTO
1
2
3
4
OFF
ON
OFF
ON
OFF
OFF
ON
ON
OFF OFF
OFF
ON
ON
ON
ON
5
6
7
ON
OFF
ON
ON
ON
OFF
OFF OFF OFF

Advertisement