Occasionally, a minor problem may arise, and a service call may not be necessary- use this troubleshooting guide for
a possible solution. If the unit continues to operate improperly, call an authorized service depot or Danby's Toll Free
Number for assistance.
PROBLEM
Unit does not work
Compressor suddenly
stops during operation
Unit runs intermittently
Unit functions but the
room is not cooled
Condensed water spills
out when moving the unit
Error Indicator Codes:
E5 - Surge protection: Disconnect the power, after 10 minutes turn the unit back on. If the warning still appears, please
contact a service provider.
H8 - Water tank is full: Drain water from the tank. If the warning still appears, please contact a service provider.
F1 - Malfunction of ambient temperature sensor: Please contact a service provider.
F2 - Evaporator sensor malfunction: Please contact a service provider.
F0 - Refrigerant leak or system blockage: Reset the unit by unplugging it for 30 minutes and then plugging it back in. If
the warning still appears, please contact a service provider.
H3 or E8 - Overload protection / malfunction: Check if the unit is operating under high temperature conditions. If the
ambient temperature is too high, turn the unit off until the ambient temperature drops below 35°C (95°F). Check to see
if something is obstructing airfl ow around the unit, if so, remove it. If the warning still appears, please contact a service
provider.
F4 - Condenser sensor is malfunctioning: Please contact a service provider.
Tel: 1-800-26-
POSSIBLE CAUSE
Power is out
The plug is not plugged in prop-
erly
The full-tank indicator is ON; tank
is full
Current leaking or pressing test
button on LCDI plug
Indoor set temperature has been
reached
The preset time is up
The full-tank indicator is ON; tank
is full
Malfunction
Surrounding temperature is too
high/low
Exhaust duct hose is blocked
Window or door is open in room
There is a heat source or too
many people in the room
Air intake grill is clogged
Filter is too dirty
Temperature setting is too high
The tank is nearly full
(1-800-263-2629)
Wait for power to return
Plug in properly
Remove drain water from the
drain tank
Press the reset button after re-
solving the problem
Reset the temperature level
Reset the timer
Remove drain water from the
drain tank
Contact your dealer
This is normal
Check the duct hose
Close all windows/doors
Move any heat sources from
room
Clean air intake grill
Replace or clean the fi lter
Lower temp. setting
Remove drain plug on rear bot-
tom and drain out water