Scheduling Function
a
• Light source calibration does not start automatically when the
projector is used continuously for more than 24 hours, or when
direct shutdown is used regularly. Set Light Source Calibration to
enable this function after every 100 hours of usage.
• You cannot register a schedule in which Schedule events conflict
with an Extended Schedule event.
• You cannot set other events before the following times.
- Five minutes before or after executing a Color Calibration event.
- Five minutes before and 30 minutes after executing a Screen
Matching event.
• When Light Source Calibration is enabled, turn on the projector at
least 20 minutes before the event.

Checking an Event

This section explains how to check a Schedule event.
a
Press the [Menu] button while projecting.
b
Select Schedule Settings from Extended.
The indicator turns on when an event is saved.
(Aqua): Single event
(Orange): Regular event
(Green): Communication monitoring On/Off
(Gray): Disabled event
117