Outdoor temperature
capacity
kBtu/h
°CDB
-15.0
-10.0
-5.0
0.0
5.0
27
7.0
10.0
15.0
20.0
24.0
NOTES:
• TC: Total Capacity (kW), IP: Input Power (kW)
• Values mentioned in the table are based on the following conditions:
– Power source of specifications: 230 V
– Pipe length: 5 m, Height difference: 0 m (Outdoor unit—Indoor unit)
• 2 or more indoor units should be connected.
• The total ability of connected a indoor unit is from 27,000 Btu/h up to 54,000 Btu/h.
• Input in the table are calculated based on the maximum indoor unit input combinations.
6-3. Heating capacity
16.0 °CDB
°CWB
TC
IP
TC
-16.0
7.0
2.50
6.8
-11.0
8.2
2.83
8.0
-7.0
8.6
2.55
8.4
-2.0
9.9
2.72
9.6
3.0
11.3
2.86
11.1
6.0
11.3
2.72
11.1
8.0
11.3
2.52
11.1
10.0
11.3
2.37
11.1
15.0
11.3
2.05
11.1
18.0
11.3
1.73
11.1
- 412 -
Indoor temperature
18.0 °CDB
20.0 °CDB
IP
TC
IP
2.56
6.7
2.61
2.89
7.8
2.95
2.60
8.2
2.65
2.78
9.4
2.83
2.92
10.8
2.98
2.78
10.8
2.84
2.58
10.8
2.63
2.42
10.8
2.47
2.10
10.8
2.14
1.77
10.8
1.81
22.0 °CDB
24.0 °CDB
TC
IP
TC
IP
6.5
2.66
6.3
2.71
7.6
3.01
7.4
3.07
8.0
2.71
7.8
2.76
9.2
2.89
8.9
2.95
10.5
3.04
10.3
3.10
10.5
2.89
10.3
2.95
10.5
2.68
10.3
2.73
10.5
2.52
10.3
2.57
10.5
2.18
10.3
2.22
10.5
1.84
10.3
1.88